Controls

Hydraulics

Hydraulic Tester: Type PPC-Pad

The hand-held measuring instrument PPC Pad helps you to deal with these new trends. It has never been so easy to follow the complex processes in these sectors with measurement, display and analysis. Potential uses include preventative maintenance, commissioning, troubleshooting and machine optimization. The expanded requirements of these modern applications (such as the increased number of measurement points, longer cable lengths and high noise immunity) have driven further development of the CAN bus.

  • Specifications
    • + expand all
    • - collapse all

    TECHNICAL DATA

    Series and Type Hydraulic Tester -
    Versions PPC-Pad-101 -
    PPC-Pad-102 -
    PPC-Pad-103 -
    Materials Housing is ABS/PC (Thermoplastic) -
    Protective Sleeve is TPE (Thermoplastic Elastomer) -
    Dimensions and Weight W x H x D: 257 x 181 x 75 mm / 10.12 x 7.13 x 2.95 in -
    Weight: 1550 g / 3.4 lbs Basic model
    Ambient Conditions Operating Temperature: 0°C to +50°C / +32°F to +122°F -
    Storage Temperature: -25°C to +60°C / -13°F to +122°F -
    Relative Humidity: < 80% -
    Environmental Test: IEC60068-2-32 1 m, free fall
    Protection Rating IP64 Dust tight and protected against splashing water
    Internal Power Supply Lithium Ion pack, +7.4 V DC / 4500 mAh Battery charging circuit/operating time with 3 CAN sensors: > 8 h
    Calibration Options (only -102 / -103) Without calibration certificate -
    With calibration certificate -
    Display FT-LCD color graphic display -
    Visible Area: 115 x 86 mm / 4.53 x 3.39 in -
    Resolution: 640 x 480 Pixel -

    MEASURED DATA MEMORY

    Memory Capacity ≤ 4 million measured values per measurement -
    Total measured value memory > 1 billion measured values -
    Memory Format ACT/MIN/MAX -
    Memory Interval 1 ms to 24 h -
    Memory Duration 1 ms to 300 h Trigger measurement
    Internal 64 MB Approximately 32 million measured values
    External SD Memory MicroSD memory card included in standard shipment -
    Slot: MicroSD memory card -
    External USB Mass Memory Device up to 40 GB -

    INPUTS / OUTPUTS

    CAN Sensor Inputs 2 CAN bus networks each with 8 sensors and max. 16 channels (for STAUFF CAN bus sensors) -
    "Scanning rate: 1 ms = 1000 measured values/sec." -
    "M12x1 push-in connector, 5-pin with SPEEDCON" -
    1 Digital Trigger Input Scanning rate: 1 ms -
    Input impedance: 1 kΩ -
    Active high: > +7 ... +24 V DC -
    Active low: < 1 V DC isolated -
    1 Digital Trigger Output Scanning rate: 1 ms -
    Max. switching signal: +24 V DC/max. 20 mA isolated -
    Push-In Connector for Digital Input and Output M8 x 1 / 4-pin, push-in connector -
    Module Slots 2, for input module, flexible placement possible -
    Slot 1 = IN1, IN2, IN3, IN4/5 -
    Slot 2 = IN6, IN7, IN8, IN9/10 -

    INTERFACE

    USB Device Online data transmission between unit and PC via PPC-Soft-plus -
    Measured value transmission: ACT/MIN/MAX -
    USB standard: 2.0, full speed -
    "Push-in connection: USB socket, shielded, type B" -
    USB Host "Standard: 2.0, full speed, 100 mA max." Connection for mass storage devices such as USB memory stick or removeable hard disc
    "Push-in connection: USB socket, shielded, type A" -
    Ethernet "Online data transmission between unit and PC via PPC-Soft-plus and remote control" -
    Measured value transmission: ACT/MIN/MAX -
    Standard: 10, 100 Mbit/s, IEEE 802.3 (10/100 base T) Push-in connection: RJ45, socket, shielded -
    Functions Measurement: ACT/MIN/MAX values -
    Measured Value Display: Numerical, bar graph, pointer, curve graph -
    Measuring Functions: Start/stop, points, trigger -
    Trigger: Slope, manual, level, window, time, logic Interconnection of up to two events for the measurement start and stop
    Pre-Trigger -
    Remote operation via the Ethernet -
    Acoustic notification at any incident -

    TECHNICAL DATA (for PPC-Pad-102 and 103)

    Input with Sensor Recognition 3 or 6 sensor inputs with sensor recognition (p/T/Q/n) for PPC Sensors Up to 6 or 12 analog measurement channels
    Push-In Connection: 5 pin, push-pull, combination panel plug/socket -
    Scanning rate of 1 ms = 1,000 measured values / second -
    For the Sensor-PPC-04/12-PT combined Pressure/Temperature Sensor, there is an additional temperature channel for each sensor input -
    Temperature scanning of 1 s -
    Inputs for Auxiliary Sensors: 2 Analog Sensor Inputs Scanning rate: 1 ms = 1000 Measured values/second
    Voltage measuring range: -10 to +10 V DC Freely configurable
    Current measuring range: 0/4 to 20 mA -
    Supply External Sensors: +18 to +24 V DC / max. 100 mA -
    Push-In Connection: M12 x 1, 5-pin socket -
    Fast Mode Scanning rate: 0.1 ms = 10,000 measured values/sec. Only one auxiliary sensor input is useable
    Accuracy +0.02% per °C -
  • Resources

    Can't find what you are looking for or need more information? Contact us

  • Request Information

      Let us know how we can help. All fields are required.


    Design - Build - Apply

    Integrated Engineered Solutions by GS Global Resources

    Browse Solutions