Direct operated 3-way pressure compensators series R5P with SAE flange can be combined with fixed or adjustable flow resistors (throttles) to provide a load compensated flow. Series R5P features a seated type 3-way pressure compensator, SAE 61 flange, 3 sizes, and optional vent function.

  • Specifications
    • + expand all
    • - collapse all

    Mechanical

    Mounting Flanged according to SAE 61 -
    Mounting Position Unrestricted -
    MTTFD 150 years -
    Maximum Operating Pressure (Ports A, B) Size 06: 350 bar (5,075 psi) -
    Size 08: 350 bar (5,075 psi) -
    Size 10: 280 bar (4,060 psi) -
    Pressure Ranges 105 bar (1,523 psi), 210 bar (3,045 psi), 350 bar (5,075 psi) -
    Nominal Flow Size 06: 90 LPM (23.8 GPM) -
    Size 08: 300 LPM (79.4 GPM) -
    Size 10: 600 LPM (158.7 GPM) -
    Fluid Hydraulic oil as per DIN 51524 ... 51535 other on request
    Fluid Temperature -20°C to +80°C (-4°F to +176°F) -
    Viscosity Permitted: 10 to 650 cSt / mm²/s (46 to 3,013 SSU) Recommended: 30 to 80 cSt / mm²/s (139 to 371 SSU)
    Filtration ISO Class 4406 (1999); 18/16/13 (acc. NAS 1638:7) -

    Electrical

    Duty Ratio 100% ED CAUTION: Coil temperature up to 150°C (302°F) possible
    Solenoid Connection Connector as per EN175301-803 -
    Protection Class IP65 in accordance with EN60529 (plugged and mounted) -
    Supply Voltage Code G0R: 12 VDC -
    Code G0Q: 24 VDC -
    Code GAR: 98 VDC -
    Code GOH: 48 VDC -
    Code W30: 110V at 50Hz 120V at 60Hz
    Code W31: 230V at 50Hz 240V at 60Hz
    Tolerance Supply Voltage Code G0R: ±10% -
    Code G0Q: ±10% -
    Code GAR: ±10% -
    Code GOH: ±10% -
    Code W30: ±5% -
    Code W31: ±5% -
    Power Consumption: Hold Code G0R: 32.7 W -
    Code G0Q: 31 W -
    Code GAR: 32 W -
    Code GOH: 30 W -
    Code W30: 70 / 70 VA -
    Code W31: 70 / 70 VA -
    Power Consumption: In Rush Code G0R: 32.7 W -
    Code G0Q: 31 W -
    Code GAR: 32 W -
    Code GOH: 30 W -
    Code W30: 280 / 290 VA -
    Code W31: 280 / 290 VA -
    Response Time Energized / De-energized AC 20/18ms, DC 46/27 ms -
    Maximum Switching Frequency AC up to 7,200, DC 70 to 16,000 switchings/hour -
    Coil Insulation Class H (180°C) (356°F) -

    Environmental

    Ambient Temperature -20°C to +50°C (-4°F to +122°F) -
  • Resources

    Can't find what you are looking for or need more information? Contact us

  • Request Information

      Let us know how we can help. All fields are required.


    Design - Build - Apply

    Integrated Engineered Solutions by GS Global Resources

    Browse Solutions