Controls

Hydraulics

FCC 10320 Flow Regulator Pressure Compensated Valve

The valve maintains a constant flow at 3, regardless of pressure variations. Flow reverse passage is free and bypasses the control orifice. To optimize regulation, the way 2 must have minimum 5 bar of back pressure.

  • Specifications
    • + expand all
    • - collapse all

    Mechanical

    Seal Type N NBR
    H HNBR
    Torque 35-38 Nm / 26-28 lb•ft -
    Max Operating Pressure 250 (3625) bar (psi)
    Flow Setting 0 ÷ 25 (5.3) l/min (gpm)
    Leakage 50 cc/min 50°C; 250 bar
    Weight 0.18 kg / 0.40 lb -
    Cavity CVS10301 -
    Regulation Type R With hexagonal allen head. A max = 51.5 [2]
    V With handwheel. A max = 51.5 [2]
    C Set-adjustment with cover cap. A max = 57.5 [2.3]
    P Factory pre-set, non-adjustable. A max = 56 [2.2]
    Adjustment Range (±10%) (l/min) 15 0 ÷ 15
    25 0 ÷ 25

    Environmental

    Operating Temperature Range -20°C + 85°C NBR seals max peak +100°C
    -20°C + 130°C HNBR seals -

    Accessories

    Valve Housing SVH10300 -
  • Resources

    Can't find what you are looking for or need more information? Contact us

  • Request Information

      Let us know how we can help. All fields are required.


    Design - Build - Apply

    Integrated Engineered Solutions by GS Global Resources

    Browse Solutions