Controls

Hydraulics

VFCT NC Limit Switch Valve Normally Closed Poppet Type

When not activated, the VFCT NC Limit Switch Valve Normally Closed Poppet Type does not allow the flow to pass from 1 to 2 whereas it allows it to pass from 2 to 1. Activating the valve allows the flow to pass from 1 to 2 and from 2 to 1.

  • Specifications
    • + expand all
    • - collapse all

    Mechanical

    Seal Type N NBR
    H HNBR
    Threads and Torque G 3/8" 35-25.8 [Nm-lbft]+/- 5%
    3/4-16 SAE 50-36.9 [Nm-lbft] +/- 5%
    M18 x 1.5 40-29.5 [Nm-lbft] +/- 5%
    Max Operating Pressure 250 (3625) bar (psi)
    Nominal Flow 40 (10.6) l/min (gpm)
    Internal Leakage 0.2 cc/min 50°C; 21cSt; 100 bar
    Weight 0.9 kg / 1.98 lb -

    Environmental

    Operating Temperature Range -20°C + 85°C NBR seals Max peak +100°C
    -20°C + 130°C HNBR seals -
  • Resources

    Can't find what you are looking for or need more information? Contact us

  • Request Information

      Let us know how we can help. All fields are required.