SC 22 Series Proportional Valves, Sectional Design
These sectional proportional valves regulate the flow rate to the actuator by means of an internal closed-loop control system. Load-independent flow control is guaranteed by individual pressure compensators upstream of each proportional direction valve (load-sensing principle). These features are accomplished via various inlet modules, various types of operators, and actuator modules with individual compensator and optional, individually adjustable, primary and secondary pressure-relief valves.
-
Specifications
- - collapse all
MECHANICAL
Design Proportional valves, sectional design, spool type - Port Port sizes to DIN 3852 - Mounting Attitude Unrestricted Ensure good air-bleeding Actuator Size A / B: G 1-1/4" - Pump Size P: G 1-1/4" - Tank Size T: G 1-1/2" - Load Sensing Size XL: G 1/4" - Pump for Pilot Stage Size X: G 1/4" - Tank for Pilot Stage Size Y: G 3/8" - Test Point for Pump Pressure Size MP: G 1/4" - ENVIRONMENTAL
Ambient Temperature Range -30°C + 60°C - HYDRAULIC
Hydraulic Fluid HL and HLP mineral oil to DIN 51524 For other fluids, please consult Bucher. Hydraulic Fluid Temperature Range -20°C to +80°C +20°C to +60°C recommended Viscosity Range 10 to 500 mm²/s (cSt) 15 to 250 mm²/s (cSt) recommended Minimum Fluid Cleanliness Class 20/18/15 Cleanliness Class to ISO 4406 : 1999 Maximum Pump Flow Rate 500 l/min - Maximum Actuator Flow Rate 340 l/min Consult Bucher for 400 l/min Maximum Pump Pressure 370 bar - Maximum Load Pressure 420 bar - Required Control △p on the Control Block 3.2 Flow Control Characteristics Request to view performance graphs Maximum Tank Pressure 50 bar - Maximum Tank Pressure for Electrohydraulic Pilot Stage 5 bar - Pilot-Pressure Range 6 to 20 bar - Pressure Rating of Pilot Circuit maximum 50 bar - ELECTRICAL
Control Current at Opening Point 24 V: 325 mA - 12 V: 650 mA - Control Current at Maximum Stroke 24 V: 680 mA - 12 V: 1,360 mA - Hysteresis with 100 Hz PWM Signal ± 3% From control current at maximum stroke Protection Class to EN 60 529 IP 65 - Insulation Class to VDE 0580 H - Supply Voltage 24 / 12 V - Coil Resistances at 20°C 24 V: 21.2 ±5% Ω - 12 V: 5.3 ±5% Ω - Coil Resistances at 60°C 24 V: 24.5 ±5% Ω - 12 V: 6.1 ±5% Ω - Power Consumption at Maximum Spool Stroke 10.4 VA Coil resistance at 60°C Relative Duty Cycle (ED) - Limiting Current 24 V: 750 mA - 12 V: 1,500 mA - -
Resources
Can't find what you are looking for or need more information? Contact us
-
Request Information