Controls

Hydraulics

RFB Return-Line Filters

RFB Return-Line Filters are designed as tank top filters. They are mounted directly on the tank top and if 100% of the system oil is filtered they provide the optimum removal of contaminant from the system. This provides the pump with clean oil thus reducing contaminant generated wear. Because of it’s low weight and compact design, they are ideally suited for mobile hydraulic applications. A high efficiency of contaminant removal is assured. The high dirt-hold capacity ensures a long service life and as a result reduced maintenance costs.

  • Specifications
    • + expand all
    • - collapse all

    Mechanical

    Construction Tank Top flange mounting -
    Filter Head Aluminum -
    Filter Bowl & Cap Glass Fiber Reinforced Polyamide -
    Sealings NBR (Buna-N®) Other sealing materials on request
    FKM/FPM (Viton®) -
    EPDM (Ethylene-Propylene-Diene-Monomer-Rubber -
    Port Connections BSP -
    NPT -
    SAE O-Ring Thread -
    Operating Pressure Maximum 10 bar / 145 psi -
    Nominal Flow Rate Maximum 185 LPM / 52 GPM -
    Media Compatibility Mineral Oils Other fluids on request

    Filter Material

    Without Filter Element Maximum △p*collapse: — -
    Micron Ratings Available: — -
    Code: O -
    Inorganic Glass Fiber Maximum △p*collapse: 25 bar / 363 psi -
    Micron Ratings Available: 3, 5, 10, 20 -
    Code: G -
    Stainless Fiber Maximum △p*collapse: 30 bar / 435 psi -
    Micron Ratings Available: 3, 5, 10, 20 -
    Code: A -
    Filter Paper Maximum △p*collapse: 10 bar / 145 psi -
    Micron Ratings Available: 10, 20 -
    Code: N -
    Stainless Mesh Maximum △p*collapse: 30 bar / 435 psi -
    Micron Ratings Available: 10, 25, 50, 100, 200 -
    Code: S -
    Note* Collapse / burst resistance as per ISO 2941 Other materials on request

    Environmental

    Temperature Range -10°C to +100°C / +14°F to +212°F -

    Options and Accessories

    Bypass Valve (integrated in the filter element) Opening pressure of 3 bar ± 0.3 bar / 43.5 psi ±4.35 psi Other settings available on request
    Clogging Indicator Options Without Clogging Indicator -
    Visual Clogging Indicator -
    Electrical Clogging Switch 42 V, N0 -
    Electrical Clogging Switch 42 V, NC -
    Electrical Clogging Switch 110 V to 230 V, two-way contact (only for Code W) -
  • Resources

    Can't find what you are looking for or need more information? Contact us

  • Request Information

      Let us know how we can help. All fields are required.


    Design - Build - Apply

    Integrated Engineered Solutions by GS Global Resources

    Browse Solutions