Cast Iron Flanges, Aluminum Body, High-Performance Single Pumps, 1.4 – 87 Displacement cm³/rev.

The Pumps GHP are high-performance single gear pumps with an aluminum body, and a cast iron flange and cover. Displacements range from 1.4 up to 87 cc/rev (Group 1, 2 and 3). Available in different configurations (European, SAE, German standard) in a single rotation or reversible version. Suitable for heavy-duty conditions, in both mobile and industrial applications.

The ALP and GHP double pumps are available as a multiple pump. By use of a modular building method front, medium, and rear pumps can be connected to each other, creating a modular pump.

  • Specifications
    • + expand all
    • - collapse all

    GHP1 Series, Group 1

    Dsiplacement 1,4 - 13,8 cc/rev -
    Max. Continuous Pressure 270 bar -
    Max. Intermitten Pressure 290 bar -
    Max. Peak Pressure 310 bar -
    Max. Speed 6000 rpm -

    GHP2 Series, Group 2

    Displacement 4,5 - 28,2 cc/rev -
    Max. Continuous Pressure 280 bar -
    Max. Intermitten Pressure 295 bar -
    Max. Peak Pressure 310 bar -
    Max. Speed 4000 rpm -

    GHP3 Series, Group 3

    Displacement 20 - 87 cc/rev -
    Max. Continuous Pressure 280 bar -
    Max. Intermitten Pressure 295 bar -
    Max. Peak Pressure 310 bar -
    Max. Speed 3500 rpm -

    Options

    Seals - -
    "V" - Viton Suitable for fluid hi-temperature applications. Range between -10°C and +120°C. In the range between -10 °C and +80°C pressures P1, P2 and P3 are possible as per the product table; beside that P1 should not be exceeded
    "VV" Version suitable for fluid at high temperatures. Range between -10°C and +150°C with max. pressure = 20 bar
    "ST" Version suitable for fluid at hi- or low-temperature applications. Range between -40°C and +120°C. In the range between -10 °C and +80°C pressures P1, P2 and P3 are possible as per the product table; beside that P1 should not be exceeded
    "H" Version suitable for fluid at low-temperature. Range between -40°C and +80°C. In the range between -10 °C and +80°C pressures P1, P2 and P3 are possible as per the product table; beside that P1 should not be exceeded
    "TR" Version suitable for inlet pressure up to max. 6 bar absolute.
    - -
    Different flanges, shafts, inlet and pressure ports -
    Reversible rotation -
    Pumps with pressure limiting valve -

    Markets

    Industrial -