This pilot operated, normally closed, proportional pressure reducing/relieving valve has a high flow capacity, low hysteresis, and no dynamic seals. A 400 Hz PWM signal is preferred and a polyurethane “D”-Ring eliminates need for backup rings.

  • Specifications
    • + expand all
    • - collapse all

    Mechanical

    Dimensions 134.80 mm (height) -
    Rated Flow (at 70 psi △P) 37.5 LPM (10 GPM) -
    Maximum Internal Leakage 0.5 LPM (0.13 GPM) at 20.7 (300 psi) 0.95 LPM (0.25 GPM) at 207 bar (3,000 psi)
    Maximum Input Pressure at Port 2 350 bar (5,000 psi) -
    Maximum Control Current 12 VDC - 0.90A 24 VDC - 0.45A
    Hysteresis at 120 Hz PWM 4% with 60% duty cycle -
    Power Consumption 9 watts at maximum reduced pressure -
    Frequency 200-600 Hz (PWM) -
    Cartridge Material All parts steel. All operating parts hardened steel. -
    Fluid Compatibility/Viscosity Mineral-based or synthetic with lubricating properties at viscosities of 45 to 2,000 SSU 6 to 420 cSt
    Filtration ISO-4406 18/16/13, SAE Class 4 -
    Weight (Approximate) 0.59 kg (1.3 lbs) -
    Cavity C10-3L Note: Requires C10-3L Cavity

    Environmental

    Operating Temperature Range/Seals -45°C to +132°C ("D"-Ring) -50°F to +270°F
    -34°C to +121°C (Nitrile) -30°F to +250°F
    -26°C to +204°C (Fluorocarbon) -15°F to +400°F

    Voltage

    Code: Omit Without Coil -
    Code: D012 12 VDC -
    Code: D024 24 VDC -