Controls

Hydraulics

CSM 1000 Contamination Sensor Module

The Contamination Sensor Module (CSM) is an online condition monitoring system for detecting particle contamination in hydraulic and lubrication fluids containing a high proportion of air bubbles. Air bubble suppression is used to dissolve the air bubbles so that they are not detected as particles. Moreover, it is the ideal solution for analyzing the particle content of fluids, independently of the rest of the hydraulic system. As an option, other condition monitoring sensors such as the AS 1000 Series Water Sensor can be incorporated.

  • Specifications
    • + expand all
    • - collapse all

    Mechanical

    Pump Type Gear pump -
    Operator Pressure -5.8 to 7.3 psi (-0.4 to 0.5 bar) standard pump
    Pin (INLET) -5.8 to 1,740 psi (-0.4 to 120 bar) pump, pressure inlet stable
    Pout (OUTLET) 73 psi (5 bar) -
    Pout (Leakage Line) 7.3 psi (0.5 bar) pump, pressure inlet stable
    Permissible Outlet Pressure 73 psi (5 bar max) -
    Connections INLET: Thread G 1/4, ISO 228 -
    OUTLET: Thread G 1/4, ISO 228 -
    Total Flow Rate Approx. 100 mL/min standard pump
    Approx. 180 mL/min pump, pressure inlet stable
    Permissible Visc. Range for Measuring 10 to 1,000 cSt -
    Permissible Fluid Temperature Range 32°F to 158°F (0°C to 70°C) -
    Permissible Fluids Hydraulic and lubrication fluids based on mineral oil -
    Power Consumption 0.18 kW @ 50 Hz -
    Motor Pump Group 0.21 kW @ 60 Hz -
    IP Class IP55 -
    Weight appox. 40 lbs. (18 kg) -

    ENVIRONMENTAL

    Ambient Temperature Range 32°F to 131°F (0°C to 55°C) -
    Storage Temperature Range -4°F to 185°F (-20°C to 85°C) -

    CONTAMINATION SENSOR

    Self-Diagnosis Continuously with error indication via status LED -
    Measuring Range Display from class ISO 9/8/7 (MIN) up to class ISO 25/24/23 (MAX) Calibrated within the range ISO 13/11/10 to ISO 23/21/18
    Power Supply Voltage 9 to 36 VDC, residual ripple < 10% -
    Power Consumption 3 W max. -
    Electrical Outputs Analog output 4 to 20 mA or 0 to 10 V RS485 interface or switching output